Lors d'opérations de maintenance, il faut parfois vérifier les dépendances entre les tiroirs CEC(U2C4E) et IO(U5877*) afin de déterminer combien de partitions doivent être arrêtées ou déplacées.

La méthode graphique depuis la HMC est la plus courante, mais il est bon aussi de pouvoir récupérer les informations en ligne de commande.

La commande à utiliser est la suivante :

getriotopology -m Mon_Chassis -o f

qui donne un affichage similaire à celui ci-dessous :

BUS_NUMBER = '1939'
LEADING_PORT_FLAG = 'External'
NODE_TYPE = 'Local NIC'
ENCLOSURE_LOC_CODE = 'U2C4E.001.DBJR146'
LEADING_PORT_LOC_CODE = 'U2C4E.001.DBJR146-P1-C2-T1'
LEADING_PORT_STATUS = 'Operational'
TRAILING_LOC_CODE = 'U2C4E.001.DBJR146-P1-C2-T2'
TRAILING_PORT_STATUS = 'Operational'
LEADING_PORT_SPEED = '12X-DDR'
POWER_CONTROL_SYSTEM_TYPE = '9117'
POWER_CONTROL_SYSTEM_SERIAL = '21-800B7'
FUNCTION_CONTROL_SYSTEM_TYPE = '9117'
FUNCTION_CONTROL_SYSTEM_SERIAL = '21-800B7'
BUS_NUMBER = '1939'
LEADING_PORT_FLAG = 'Internal'
NODE_TYPE = 'Local Bridge'
ENCLOSURE_LOC_CODE = 'U5877.001.9K8S030'
LEADING_PORT_LOC_CODE = 'U5877.001.9K8S030-P1'
LEADING_PORT_STATUS = 'Operational'
TRAILING_LOC_CODE = 'U5877.001.9K8S030-P1-T1'
TRAILING_PORT_STATUS = 'Operational'
LEADING_PORT_SPEED = '12X-DDR'
POWER_CONTROL_SYSTEM_TYPE = '9117'
POWER_CONTROL_SYSTEM_SERIAL = '21-800B7'
FUNCTION_CONTROL_SYSTEM_TYPE = '9117'
FUNCTION_CONTROL_SYSTEM_SERIAL = '21-800B7'
BUS_NUMBER = '1939'
LEADING_PORT_FLAG = 'Internal'
NODE_TYPE = 'Local Bridge'
ENCLOSURE_LOC_CODE = 'U5877.001.9K8S030'
LEADING_PORT_LOC_CODE = 'U5877.001.9K8S030-P1'
LEADING_PORT_STATUS = 'Operational'
TRAILING_LOC_CODE = 'U5877.001.9K8S030-P1'
TRAILING_PORT_STATUS = 'Operational'
LEADING_PORT_SPEED = '12X-DDR'
POWER_CONTROL_SYSTEM_TYPE = '9117'
POWER_CONTROL_SYSTEM_SERIAL = '21-700B7'
FUNCTION_CONTROL_SYSTEM_TYPE = '9117'
FUNCTION_CONTROL_SYSTEM_SERIAL = '21-700B7'
BUS_NUMBER = '1939'
LEADING_PORT_FLAG = 'External'
NODE_TYPE = 'Local Bridge'
ENCLOSURE_LOC_CODE = 'U5877.001.9K8S030'
LEADING_PORT_LOC_CODE = 'U5877.001.9K8S030-P1-T2'
LEADING_PORT_STATUS = 'Operational'
TRAILING_LOC_CODE = 'U5877.001.9K8S030-P1'
TRAILING_PORT_STATUS = 'Operational'
LEADING_PORT_SPEED = '12X-DDR'
POWER_CONTROL_SYSTEM_TYPE = '9117'
POWER_CONTROL_SYSTEM_SERIAL = '21-700B7'
FUNCTION_CONTROL_SYSTEM_TYPE = '9117'
FUNCTION_CONTROL_SYSTEM_SERIAL = '21-700B7'