L'erreur ci-dessous peut apparaître lorsque le service RSCT réagit trop vite et ne reconnaît plus ses interfaces.
Le bogue est retiré dans certaines versions du produit, et ne prête pas à inquiétude particulière.
Description
NIM thread blocked
Probable Causes
A thread in a Topology Services Network Interface Module (NIM) process
was blocked
Topology Services NIM process cannot get timely access to CPU
User Causes
Excessive memory consumption is causing high memory contention
Excessive disk I/O is causing high memory contention
Recommended Actions
Examine I/O and memory activity on the system
Reduce load on the system
Tune virtual memory parameters
Call IBM Service if problem persists
Failure Causes
Excessive virtual memory activity prevents NIM from making progress
Excessive disk I/O traffic is interfering with paging I/O
Recommended Actions
Examine I/O and memory activity on the system
Reduce load on the system
Tune virtual memory parameters
Call IBM Service if problem persists
Detail Data
DETECTING MODULE
rsct,nim_control.C,1.39.1.41,7916
ERROR ID
6BUfAx.SSiTI/uWW08qWi.1...................
REFERENCE CODE
Thread which was blocked
send thread